Monitoring of a pressurized water circle system

- possibility to monitor acoustic emissions and accelerations during operative pressurization of storage tanks
- possibility to run pressurization cycles (time, loading/unloading) at will
- datasets of acoustic emission related to pencil break and water spilling available for source detection/localization
- open for any type of sensing device compliant with steel pipes and steel vessels

Owner:
University of Bologna, Italy

Types of sensing
accelerations, acoustic emissions, pressure, temperature

Loading type
water pressurization up to 16,7 bar

Access to externals
Yes; any time; contact: alessandro.marzani@unibo.it

Implementation of additional sensors
Any to be discussed

Type of data available
lidar, CAD; pressure history loading; Acoustic emission and accelarations

Availability of recorded data to externals 
Yes; contact: alessandro.marzani@unibo.it